MenuBack
-
Menu
-
Arduino & Raspberry & Micro:bit
-
-
-
-
-
Controller Boards
-
-
-
Batteries
-
Components & TOOLS
-
-
e-Textil
-
-
-
Interruptores & Botões
-
-
-
Sound and Audio
-
-
-
Comunication & Smart Home
-
-
LCD + Matrix + Keypad
-
-
Power Sources and Renewable Energy
-
-
-
RENEWABLE ENERGY
-
-
-
3D Printing & DRONES
-
-
Informática
-
-
Informática
-
-
-
Motors and Relays
-
-
Oficina & Equipamentos
-
-
Oficina & Equipamentos
- Cable ties
- Pliers and Wrenches
- Breadboards
- Drills and Milling Cutters
- Storage Boxes
- Electronics boxes
- Bench Equipment
- Tool Cases & Kits
- Heat shrink sleeve
- Multimeters
- Oscilloscope
- Screws and Spacers
- PCB Copper
- End-Sleeves
- IC Programmers
- Personal Protection
- Protoboards
- Soldering
- Spray and Conductive Paint
- DIN Rail Supports
- Others
-
-
-
ROBOTICS
-
-
Sensors
-
-
- Catalog
- New Products
- On Sale
- Tutorials
- Contact
Heart rate sensor module MAX30102 - pulse sensor
The MAX30102 module uses a red LED (660nm), infrared LED (880nm), and photodetector to approximate blood oxygen content and heart rate pulses. The sensor can be placed on a finger, wrist, or other area with significant blood flow to measure these parameters.
If you have any questions on this product please feel free to contact us.
*Disclaimer: The images are merely illustrative.
The Main Parameters:
LED peak wavelength: 660nm/880nm
LED power supply voltage: 3.3~5V
Detection signal type: light reflection signal (PPG)
Output signal interface : I2C interface
Communication interface voltage: 1.8~3.3V~5V (optional)
Board reserved assembly hole size: 0.5 x 8.5mm
Pin Description:
VIN: main power input terminal 1.8-5V
3-bit pad: Select the pull-up level of the bus, depending on the pin master voltage, select 1.8v or 3_3v (this terminal contains 3.3V and above)
SCL: the clock connected to the I2C bus;
SDA: data connected to the I2C bus;
INT: Interrupt pin of the MAX30102 chip;
RD: RED LED ground terminal of MAX30102 chip, generally not connected;
IRD: The IR LED ground of the MAX30102 chip is generally not connected;
GND: Ground wire.
Principle Description:
Light-dissolving method: measuring the pulse and blood oxygen saturation by using human tissue to cause different transmittance when the blood vessel beats;
Light source: a specific wavelength of light-emitting diode selective for oxyhemoglobin (H bO 2 ) and hemoglobin ( Hb ) in arterial blood;
The transmittance is converted into an electrical signal: the change in the volume of the arterial pulsation causes a change in the transmittance of the light. At this time, the
photoelectric variator receives the reflected light from the human tissue, converts it into an electrical signal, and amplifies and outputs it.